3. Environmental test |
No. |
Test items |
Test condition |
Standard |
1 |
High temp storage test |
144 hours at + 85 ºC |
After the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value |
2 |
Low temp storage test |
144 hours at - 40 ºC |
3 |
High temp and high humidity storage test |
144 hours at + 65 ºC and 85 ± 5% RH |
4 |
Thermal shock test |
Parallel 3.9k Ω resistor at both ends of the probe, keep the temp at - 40 ± 5 ºC for 0.5h, and increase the temp to 85 ± 5 ºC within 5 minutes and keep for 0.5h.100 cycles. |
After the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value |
5 |
Vibration test |
Products bear the vibration with frequency 10-55hz, amplitude 1.5mm,and sweep rate 1oct / min, from X, Y and Z directions for each 2 hours respectively |
After the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value |
6 |
Monomer drop test |
15 free fall tests carried out from 100 ± 10cm height to 50mm thick wooden floor |
After the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value |
7 |
Strength test of outlet |
Apply 9.8N pulling force between shell and wire for 30 seconds |
The wire is not loose or falling off, the product function is normal, and the wire is not damaged |
8 |
Protection level |
Place the probe in 15cm deep water and soak for 24 hours |
Take out the capasual from the water and install it on the test board to measure the distance. The probe works normally without long sound. |
9 |
High and low temp characteristic test |
Keep the temp at -40ºC for 2h,increase to 25ºC and keep for 2h,increase to 85ºC and keep for 2h. |
After the test and place in + 25 ºC (room temp) for 2 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value |
10 |
High and low temp working test |
Under high temp 85 ºC, low temp - 40 ºC, working voltage 140 Vp-p, pulse number 20, continuous working 48 hours |
Probe works normally (sensitivity and residual vibration are within normal range) |