• Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino
  • Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino
  • Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino
  • Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino
  • Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino
  • Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino

Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino

Type: Open Ultrasonic Sensors
Output Signal Type: Analog Type
Production Process: Integration
Samples:
US$ 5/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino pictures & photos
Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino
US $0.98-1.02 / Piece
Min. Order: 100 Pieces
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5

Basic Info.

Model NO.
KT40-096
Sensitivity
Medium
Probe Type
Ultrasonic
Measuring Medium
Air
Detection mode
Direct Reflection Type
IP Rating
None
Certification
RoHS
Customized
Customized
Transport Package
Customization
Specification
customization
Trademark
customization
Origin
China
HS Code
85261090
Production Capacity
10K/Day

Packaging & Delivery

Package Size
8.00cm * 4.00cm * 4.00cm
Package Gross Weight
0.200kg

Product Description

1, Part Description:
1 Independent RX and TX
2 Water proof
3 extension wire harness (Dia 3.0mm x 200mmL)
4 2P connect with capsule. Left for positive and right for negative with copper Pin
             
2, Electronic specification & physical character
  Description Standard or testing result   Item Description Standard or testing result
1 Part Number KT40-096 8 Detective angle 30°±15°
2 Match sensor number KT40-T/R1212 9 Intermittent space (ms) 50
3 Center frequency(KHz) 40±1KHz 10 Protocal TTL
4 Operation voltage 5V 11 Connect  JST: B04B-XNISK-A-1  or custermization
5 Operation current 20mA 12 Sensor colour Natural aluminum or customization
6 Detective distance
(Max.)
4m 13 Stock temperature -10ºC~+60ºC
7 Blind detective distance  4cm±1cm 14 Operation temperature '+25ºC~+10ºC
 
3,Dimension and detective diagram

Kt40-096 Ultrasonic Sensor Module with Optional Frequency for Measuring of Arduino
4. Environmental test
No. Test items Test condition Standard
1 High temp storage test 144 hours at + 85 ºC After the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value 
2 Low temp storage test 144 hours at - 40 ºC
3 High temp and high humidity storage test 144 hours at + 65 ºC and 85 ± 5% RH
4 Thermal shock test Parallel 3.9k Ω resistor at both ends of the probe, keep the temp at - 40 ± 5 ºC for 0.5h, and increase the temp to 85 ± 5 ºC within 5 minutes and keep for 0.5h.100 cycles. After the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value 
5 Vibration test Products bear the vibration with frequency 10-55hz, amplitude 1.5mm,and sweep rate 1oct / min, from X, Y and Z directions for each 2 hours respectively After the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value 
6 Monomer drop test 15 free fall tests carried out from 100 ± 10cm height to 50mm thick wooden floor After the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value
7 Strength test of outlet Apply 9.8N pulling force between shell and wire for 30 seconds The wire is not loose or falling off, the product function is normal, and the wire is not damaged
8 Protection level Place the probe in 15cm deep water and soak for 24 hours Take out the capasual from the water and install it on the test board to measure the distance. The probe works normally without long sound.
9 High and low temp characteristic test Keep the temp at -40ºC for 2h,increase to 25ºC and keep for 2h,increase to 85ºC and keep for 2h.  After the test and place in + 25 ºC (room temp) for 2 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value
10 High and low temp working test Under high temp 85 ºC, low temp - 40 ºC, working voltage 140 Vp-p, pulse number 20, continuous working 48 hours Probe works normally (sensitivity and residual vibration are within normal range)
             
             
5.Test conditions and instruments
No. Test item Test instruments/method Test condition
1 resonant frequency Impedance analyzer ambient temperature 25 ± 5 ºC
2 static capacitance LCR bridge measuring instrument ambient temperature 25 ± 5 ºC
3 residual oscillation KT test equipment ambient temperature 25 ± 5 ºC
4 sensitivity KT test equipment 0.8m at room temperature, target Φ 75mm PVC pipe
5 Angle (X & Y axis) KT test board, as per Fig.1 Under normal room temperature, the probe is 500mm from the ground, 500mm from the object to be detected, and the object to be detected is Φ 75mm PVC pipe, 1000mm high. The test environment: 2 meters in front and 1.5m in the left and right without obstacles
6 Maximum allowable input voltage KT test board and Oscilloscope 140vp-p, pulse width 0.5ms,
intermittent: 10ms
7 Mean time between failures aging test rack Test temp 25±5ºC
             
6.Precautions
1. Please confirm with us which industry will be used before purchasing for selection.
2. In order to prevent the sensor from failure, working failure or performance degradation, the anti failure
   function shall be added to the product design, and the product shall not be used under the following or
   similar conditions.
   (a) strong shock or vibration
   (b) prolonged exposure to high temperature and humidity;
   (c)In corrosive gas or sea breeze
   (d)Exposure to dissolved organic matter
   (e)Dusty environment;
   (f)Over allowable input voltage
 
7.Quality assurance
The sensor defects due to the manufacturer during the warranty period of the product can be replaced free of charge.
The following situations are not covered by the warranty.
1, improper use or handling by users. 
2, changed or repaired by the users. 
3,any other situation that does not belong to the responsibility of the manufacturer, such as natural disasters, accidents, etc.

Send your message to this supplier

*From:
*To:
avatar Miss Molly
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now